Skip to main content

CISPR 16-1-4:2010

Superseded Date published:

Warning: Superseded Standard. This document has been replaced by:

CISPR 16-1-4:2019

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements

CISPR 16-1-4:2010 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included. The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in Part 2-3, and further information on radio disturbance is given in Part 3 of CISPR 16. Uncertainties, statistics and limit modelling are covered in Part 4 of CISPR 16. This third edition of CISPR 16-1-4 cancels and replaces the second edition published in 2007 and its Amendments 1 (2007) and 2 (2008). It is a technical revision. This edition includes the following significant technical change with respect to the previous edition: provisions are added to address evaluation of a set-up table in the frequency range above 1 GHz. CISPR 16-1-4:2010 has the status of a basic EMC publication in accordance with IEC Guide 107, Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications

Get this standard Prices exclude GST
PDF ( Single user document)
$700.87 NZD
HardCopy
$769.57 NZD
Networkable PDF
Price varies
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next

Keep me up-to-date

Sign up to receive updates when there are changes to this standard

Related Information

Similar Standards

  • AS/NZS 61000.2.4:2009

    Electromagnetic compatibility (EMC) - Environment - Compatibility levels in industrial plants for low frequency conducted disturbances

  • AS/NZS 61000.3.4:2007

    Electromagnetic compatibility (EMC) - Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 75 A

  • AS/NZS 61000.4.14:2012


    Electromagnetic compatibility (EMC) - Part 4.14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase

  • AS/NZS 61000.4.20:2023

    Electromagnetic compatibility (EMC), Part 4.20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides (IEC 61000-4-20:2022 (ED. 3.0) MOD)

Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next

CISPR 16-1-4:2010

Get this standard Prices exclude GST
PDF ( Single user document)
$700.87 NZD
HardCopy
$769.57 NZD
Networkable PDF
Price varies

Request to add this standard to your subscription

CISPR 16-1-4:2010

Price varies
Online library subscription

Your organisation’s Account Administrator must approve a request to add a standard to your subscription.

You may add a comment to the administrator below.

Cancel